As we all know, there are many benefits of installing big air industrial fans in various industries. Whether the installation sequence of large industrial fans is correct will directly affect the safety issues in future use. So, what should be the correct installation sequence for large industrial fans?
1. Install the bottom plate
Install the bottom plate according to the installation position, the two sides of the bottom plate are equidistant, the bottom plate and the installation beam should cross vertically, and the upper surface of the backplate should be flat. Completely combine the installation pressure plate with the I-beam, and install the backplate. After leveling, fasten with high-strength bolts, and other fixing and installation methods all meet the same standard.
2. Install the host
The main body of a hvls ceiling fan is very heavy, so special attention should be paid when installing it. Use a level to measure the verticality of the rod to be installed at 90 degrees. When the beam itself has an inclination, the verticality can be adjusted through the half-moon bolt holes on the bottom plate and frame ears.
During installation, the upper and lower planes of the host should be kept level to ensure that the fan body sags naturally. Use a level to measure, and then tighten all fasteners. The best part of the pressure plate must be pressed on the backplate to avoid loosening.
3. Install safety rope
The safety wire rope goes around the girder of the factory building, connects the fan host to the girder, and then locks it with the wire rope to enhance safety protection.
4. Install wires
First, determine the fixed positions of the 4 steel wire zippers, move the lifting equipment to make holes, and then start to fix the steel wire ropes. When tightening the wire rope, the bolt main machine safety wire rope directly connects the main machine and the room beam. The wire rope should be of medium length, equidistant, symmetrical, and the force is even. Tighten the four-wire ropes to adjust the large industrial fan. After tightening the wire rope clamp and the wire rope, thread fastening glue should be applied to prevent the wire rope from loosening after being stressed.
5. Host wiring, threaded cable
Do not scratch the surface of the cable. Do not cut the copper wire when stripping. First, connect the black thin wires of the grounding wire, and then connect the colors one by one, and then wrap them with insulating tape to ensure the safe operation of the product. Then take the cables out of the rack and route them according to the site conditions.
6. Install fan blades and logo
It is recommended that two people cooperate when installing the fan blades. Use high-strength hinged bolts to fix the fan blades, and install the fan blades diagonally to ensure uniform force. Do not scratch the surface of the fan blade and tighten the effect. After installing the fan blade, the two ends of the wire rope passing through the fan blade pass through the corresponding connecting bolt hole from bottom to top, the two rope heads are combined on the upper part of the leaf handle, and the corresponding wire rope clamp is used for locking and fixing. The wire rope cutter can cut the excess wire rope.
7. Install the fan blade safety ring
When installing the fan blade connecting plate, when connecting the two connecting plates together, one end of the one-shaped hole faces down, and one end of the round hole faces up. Use high-strength bolts to install in order, and then form a ring to connect all the blades. Connect each other, and then apply thread fastening glue to ensure the reliable operation of large industrial fans.
Source: Gaxiaofan Press Department